Display Type
10.4" Wide Color TFT LCD
ECG Lead
3 / 5 Leads
HR Measurement Range
20-30bpm(+3bpm or +3%)
Sweep Speed
6.25, 12.5, 25mm/s
Lead-off Detection
Yes
CMRR
>90dB at 50 or 60Hz
Gain
5, 10, 20mm/mV
Pulse Oximetry(Sp02) Sp02 Range
0~100%
Sp02 Accuracy
Adult/Pediatric : 70~ 100% +2% Neonate : 70 ~ 100% +3% 0 ~ 69% : Unspecified
Pulse Rate Range
20~ 250bpm(+-1% or +-1bpm)
Perfusion Range
0.05 ~ 20%
Temperature Measurement Measurement Method
Thermistor
Compatible with
YSI Series 400 Temperature Probes
Measurement Range
10 to 45°C (50 to 113°F)
Measurement Accuracy
+-0.1°C(25~45C)
Parameter Displayed
+-0.2°C(10 ~ less than 25°C)
EtC02 (Option)Built-in Respironics Sidestream Method Type
Non-dispersive Infrared Single Beam Optics, Dual Wavelength, No Moving Parts
C02 Measurement Range
0~ 150mmHg 0~ 40mmHg+2mmHg 41~ 70mmHg+5% of Reading 71~ 100mmHg+8% of Reading 101~ 150mmHg+10% of Reading
Respiratory rate Range
2~ 150bpm +1 breath
PC Interface
RS232C or LAN
Trend
72 hours of Tabular and Graphic Trend data
Respiration Technology
Trans-thoracic Impedance
Leads
RA to LA
Range
0 ~ 150 breaths/min
Accuracy
+-2 breaths/min
Noninvasive Blood Pressure(NiBp) Technology
Oscillometric Method
Measurement Mode
Auto, Manual, STAT
Auto Mode Interval
1,3,5,10,30,60,90,120,240min
Systolic Pressure Range
Adult/Pediatric : 50 ~ 255mmHg Neonate : 30 ~ 130mmHg
Diastolic Pressure Range
Adult/Pediatric : 30~ 220mmHg Neonate : 20 ~ 100mmHg
Mean Pressure Range
Adult/Pediatric : 40 ~ 235mmHg Neonate : 25 ~ 120mmHg
Pressure Display Range
0 ~ 300mmHg
Pressure Display Accuracy
Less than +-3mmHg
IBP Channel
2 Channels
Method Type
Pressure Transducer
Pressure Range
-50~ 300mmHg
Parameter Display Trans-thoracic Impedance RA to LA 0 ~ 150 breaths/min · +2 breaths/min 6.25, 12.5, 25mm/s . Oscillometric Method . Auto, Manual, STAT 1,3,5,10,30,60,90,120,240min 2 Channels Pressure Transducer 20~ 250bpm(+1% or +1bpm) · -50~ 300mmHg P1,
P1, ABP, P2, CVP, PAP, LAP
Printer (Option) Type
Thermal
Paper Speed
50mm/s
Paper Size
2 inch (50.8mm)
Weight
153g
Resolution
203 dpi : 8 dots/mm
External Interface
VGA
Power Voltage
Input : AC 100~ 240V (50/60Hz)
Consumption
100VA
Fuse
250V/5A
Rechargeable Battery
Li-ion(11.1VDC / 2,200mAh] Operating Time : 3hrs (no printing, sound, external link)
Standard Configuration
Sp02 Reusable Sensor 1ea, Sp02 Extension Cable 1es, Power cord 1ea, operation manual 1ea, NiBp Cuff(adult) 1ea, NiBp Extension Hose 1ea, ECG Cable 3 Lead type 1ea, ECG Ecectrode(3M) 3ea
Options
Sp02 Finger Probe & Disposable Sensor, Printer Module, EtC02 Kit Set, IBP Kit, NiBp Cuff(Big Adult, Child, Pediatric, Infant), ECG Cable 5 Lead Type, Temperature Sensor, LAN Card
Warranty
Main Unit 2years
Dimension
Main Unit · 257(W) x 158(D) x 236[H]mm, Packing 420(W) x 360[D) x 350[H]mm, Main 3Kg, Packing 6.3Kg
Environmental Conditions
Operating Temperature - 10~ 40°C (50~ 104°F), Operating Humidity - · 15~90% non-condensing, Storage Temperature -20~ 50°C (-4~ 122°F), Storage Humidity - 15 ~ 95% non-condensing
Certificates
KFDA, CE
Standard
IEC60601-1, IEC60601-1-2